UHT

High Temperature Series

The UHT series is Ultracell's high temperature VRLA battery range, available in 2V and 12V. It is built to limit grid corrosion, electrolyte loss and dry-out, so it keeps its performance and service life longer than conventional VRLA batteries in hot environments. Made with high-purity lead and strong ABS housings, each battery is tested under elevated temperatures, not just standard room conditions, before it leaves the factory.*

* Applies to selected models.

Ultracell UHT High Temperature Series battery range

Key Features

High Temperature Tolerance

Rated for discharge from -15°C* to 70°C* in high-temperature environments without climate control.

Thermal Stability

Maintains stable performance and capacity retention even where ambient temperatures stay consistently high.*

Specialised Construction

Heat-resistant materials and enhanced internal design help offset the effects of sustained high heat.

Consistent Performance

Reliable operation even under thermal stress conditions where standard batteries would age faster.*

Extended Life

Design life of up to 15 years for 2V models and 10 years for 12V models.

Industrial Grade

Built to industrial standards for reliable performance in harsh, uncontrolled-climate environments.

* Applies to selected models.

Specifications

UHT-12V
Select a model · 12V
3 models

View another voltage

UHT High Temperature Series

The UHT series is engineered specifically for operation at elevated temperatures, with its internal construction optimised to resist the accelerated ageing processes caused by heat. High-temperature operation places increased stress on the positive grids, active material, separators and electrolyte, so the battery is designed to limit corrosion, electrolyte loss and premature dry-out while maintaining stable plate contact. This allows the UHT series to retain performance and service life more effectively than conventional VRLA batteries in sustained high-temperature environments.

Design & Build Quality

Each UHT battery is manufactured under Ultracell's strict quality framework, combining high-purity lead, strong ABS housings, and precision-controlled assembly at every stage of production. Comprehensive testing verifies long-term performance specifically under elevated temperature conditions, rather than standard ambient testing alone, confirming durability and safety before any unit leaves the factory. This process ensures the UHT series performs consistently wherever it's deployed, even in the most thermally demanding installations.

Applications

Telecoms

  • Outdoor base stations
  • Control cabinets and network enclosures
  • Relay and switching equipment
  • Backup systems for remote telecom infrastructure

Utilities

  • Substation control and grid monitoring
  • SCADA and automation systems in harsh climates
  • Energy distribution and relay network backup
  • Temperature-resilient systems for grid stability

Industrial

  • Rail and transport signalling systems
  • Process control and automation
  • Industrial enclosures, mining, and heavy-duty plant operations

Renewable Energy

  • Solar and hybrid installations in hot regions
  • Renewable-powered telecom and utility systems
  • Off-grid industrial and communication backup
  • Energy storage for desert or tropical climates

Emergency Power

  • Lighting, control, and safety systems
  • Backup power for critical facilities
  • Standby for temperature-variable environments
  • Emergency support in outdoor installations

Network Infrastructure

  • Base stations and communication towers
  • Data transmission and relay hubs
  • Fibre and cable network backup in harsh conditions
  • Control and monitoring units for remote networks

Frequently Asked Questions

The UHT series is Ultracell's high-temperature valve-regulated lead acid (VRLA) battery range, rated for discharge from -15°C* to 70°C*. Unlike conventional VRLA batteries, whose service life can deteriorate rapidly when continuously exposed to elevated temperatures, the UHT series is specifically engineered to maintain performance and extend service life under sustained high-temperature conditions.

* Applies to selected models.

UHT batteries are used in telecoms cabinets, utilities, and industrial installations without climate control, where ambient temperatures regularly exceed the 40–50°C* range standard VRLA batteries are rated for. The -15°C* to 70°C* discharge range makes them suited to plant rooms, outdoor enclosures, and other locations where cooling isn't practical or available.

* Applies to selected models.

The UHT series is tested to IEC 60896-21 &22, the international standard for stationary lead acid batteries, and rated for discharge across -15°C* to 70°C*.

* Applies to selected models.

The UHT series uses a standard top-terminal layout, while the UHTFT series combines the same high-temperature construction with a front-terminal design for cabinet and rack installations.